Skip to content

2.5 Complete isolated-water calculation

The inputs on this page are educational templates that have not been executed for this course. Use an authorized installation, verify version-specific options and establish your own convergence.

2.5.1 Define the physical question

Compute PBE electronic energy and forces for fixed neutral closed-shell water in vacuum. This is not liquid water, a molecular crystal, zero-point correction or free energy. The reasonable original geometry is not asserted to be optimized. Save complete water_sp.inp with local verified data files. The 500/60 Ry grid pair is an unvalidated starting choice.

&GLOBAL
  PROJECT water_sp
  RUN_TYPE ENERGY_FORCE
  PRINT_LEVEL MEDIUM
&END GLOBAL

&FORCE_EVAL
  METHOD QUICKSTEP
  &DFT
    BASIS_SET_FILE_NAME BASIS_MOLOPT
    POTENTIAL_FILE_NAME GTH_POTENTIALS
    CHARGE 0
    MULTIPLICITY 1
    &QS
      METHOD GPW
      EPS_DEFAULT 1.0E-12
    &END QS
    &MGRID
      NGRIDS 4
      CUTOFF [Ry] 500
      REL_CUTOFF [Ry] 60
    &END MGRID
    &POISSON
      PERIODIC NONE
      POISSON_SOLVER MT
    &END POISSON
    &SCF
      SCF_GUESS ATOMIC
      EPS_SCF 1.0E-7
      MAX_SCF 100
      &OT
        MINIMIZER DIIS
        PRECONDITIONER FULL_ALL
      &END OT
    &END SCF
    &XC
      &XC_FUNCTIONAL PBE
      &END XC_FUNCTIONAL
    &END XC
  &END DFT
  &SUBSYS
    &CELL
      ABC [angstrom] 18.0 18.0 18.0
      PERIODIC NONE
    &END CELL
    &COORD
      UNIT angstrom
      O  9.000000  9.000000  9.000000
      H  9.758602  9.000000  9.504284
      H  8.241398  9.000000  9.504284
    &END COORD
    &KIND O
      BASIS_SET DZVP-MOLOPT-SR-GTH
      POTENTIAL GTH-PBE-q6
    &END KIND
    &KIND H
      BASIS_SET DZVP-MOLOPT-SR-GTH
      POTENTIAL GTH-PBE-q1
    &END KIND
  &END SUBSYS
  &PRINT
    &FORCES ON
    &END FORCES
  &END PRINT
&END FORCE_EVAL

Verify exact H/O labels in your actual BASIS_MOLOPT and q1/q6 in GTH_POTENTIALS. Standard data provide these GTH-compatible labels, but a file merely containing “DZVP” is not interchangeable. Official first-calculation structural reference has different coordinates/settings.

2.5.2 Geometry and electrostatics have separate periodicity

CELL/PERIODIC NONE governs subsystem geometry; POISSON/PERIODIC NONE specifies electrostatic boundaries. Both are intentional. A large box with periodic electrostatics remains periodic. The Martyna–Tuckerman solver requires a cell at least twice the spatial charge-density extent for its exactness guarantee, including electronic tails rather than only nuclear bounding box. Test finite-box sensitivity. MT requirements.

2.5.3 Execute and inspect

cp2k -i water_sp.inp -o water_sp.out
status=$?
printf 'exit_status=%s\n' "$status"
grep -nE 'SCF run converged|ENERGY\||ATOMIC FORCES|PROGRAM ENDED' water_sp.out

Use the scheduler on clusters. Grep only locates evidence: read context/end and exclude stale logs. Confirm intended version/path, three atoms, H/O kinds, eight valence electrons, singlet, explicit SCF convergence, no later fatal error, total energy and three force vectors with consistent headers. Nonzero forces are expected before optimization. A small force-vector sum is a useful diagnostic, not proof that individual forces vanish.

Absolute energies use method-dependent pseudopotential references. Offsets from all-electron molecular codes do not by themselves diagnose failure. Record output units, model and actual values rather than expected-looking numbers.

2.5.4 Exercise

Create an evidence table for each acceptance check, retaining input, raw output, data hashes and version. Identify how ENERGY_FORCE differs from GEO_OPT. If unexecuted, annotate the complete input and leave energy/force fields blank.


Previous:Environment, GPW and the input tree · Next:SCF, grids and basis: separate tests