Skip to content

3.4 Finite-strain elasticity: clamped ions versus relaxed ions

These are unexecuted teaching inputs and starting models. Original diagrams are schematics, not calculated results. Validate version-specific syntax, licensed or authorized data, numerical convergence and the scientific model before using this workflow.

3.4.1 Model, units and provenance

PW cutoffs and energies use Ry, common force output uses Ry/bohr, and pressure uses kbar. Geometry cards state their coordinate units. Different executables have distinct grammars and time-unit conventions.

Shared inputs, conventions and evidence

Original schematic: Finite-strain elasticity: clamped ions versus relaxed ions. No numerical results are claimed.
Original schematic: Finite-strain elasticity: clamped ions versus relaxed ions. No numerical results are claimed.

3.4.2 Unexecuted inputs and explicit deltas

Use the accompanying instructions to identify the parent calculation and placement of every delta; a snippet is not automatically a standalone input. Preserve all blank-line and file-provenance requirements.

3.4.2.1 Input block 1

Convert equilibrium Si to ibrav=0 and CELL_PARAMETERS angstrom.
Use deformation F = I + epsilon and transform each lattice vector.
Normal experiment: epsilon_xx = {-0.010,-0.005,0,+0.005,+0.010}
Shear experiment: epsilon_xy = epsilon_yx = gamma/2
                 gamma = {-0.010,-0.005,0,+0.005,+0.010}
Keep fractional coordinates fixed for clamped-ion SCFs.
For relaxed-ion response: calculation='relax', fixed strained cell.

3.4.3 Worked investigation

3.4.3.1 Intuition and prerequisites

Elastic constants are derivatives of stress with respect to strain. In a multi-atom cell, internal coordinates may relax under strain, changing the response. This case uses Si at its converged equilibrium cell and builds small positive and negative strains. QE supplies energies, forces and stresses; the strain generator and tensor fit are external analysis steps, not a universal built-in “elastic constants” tag.

3.4.3.2 Original deformation protocol

See input block 1 above.

3.4.3.3 Outputs, checks and exercise

Deliver the full stress–strain table, sign convention, Voigt ordering, fit slopes and unit conversion. Test smaller and larger strain windows: too small amplifies numerical noise; too large leaves the linear regime. Check cubic stability inequalities C₁₁−C₁₂>0, C₁₁+2C₁₂>0 and C₄₄>0 for the intended stable zero-pressure phase, without using them to conceal negative results. Exercise: compare the bulk modulus (C₁₁+2C₁₂)/3 with Case 3.3 and diagnose discrepancies.

3.4.3.4 Electronic interpretation

3.4.5 Sources and further reading