4.6 Hybrid silicon: converge exchange sampling separately
These are unexecuted teaching inputs and starting models. Original diagrams are schematics, not calculated results. Validate version-specific syntax, licensed or authorized data, numerical convergence and the scientific model before using this workflow.
4.6.1 Model, units and provenance
PW cutoffs and energies use Ry, common force output uses Ry/bohr, and pressure uses kbar. Geometry cards state their coordinate units. Different executables have distinct grammars and time-unit conventions.
Shared inputs, conventions and evidence
4.6.2 Unexecuted inputs and explicit deltas
Use the accompanying instructions to identify the parent calculation and placement of every delta; a snippet is not automatically a standalone input. Preserve all blank-line and file-provenance requirements.
4.6.2.1 Input block 1
! Fresh Si-base copy with a new prefix and directory.
! SYSTEM additions for an HSE starting test:
input_dft='HSE', nqx1=2, nqx2=2, nqx3=2
! Keep a documented k mesh; initially 4x4x4 for a small test.
! Do not alter exx_fraction or screening_parameter casually.
4.6.3 Worked investigation
4.6.3.1 Intuition and prerequisites
Hybrid functionals add nonlocal exchange, which brings a second reciprocal-space convergence problem and substantial cost. Use Si as a small benchmark, with a pseudopotential suitable for the intended comparison. A hybrid gap is still not automatically an optical excitation energy. Do not assume that every semilocal post-processing or response route is available unchanged for hybrids.
4.6.3.2 Original starting delta
See input block 1 above.
4.6.3.3 Outputs, checks and exercise
Distinguish outer exact-exchange convergence from ordinary inner electronic convergence. A small inner residual alone is insufficient. For band paths, consult the installed version's supported hybrid-band procedure rather than applying an arbitrary semilocal bands/NSCF recipe; interpolation or specialized added-k workflows have their own conditions. Exercise: compare a fixed-geometry PBE/HSE result with separately relaxed geometries and separate the functional effect from the structural effect. Do not present a coarse test as production-quality because the plot looks smooth.
4.6.3.4 Surfaces and defects
4.6.4 Related calculations
- 4.5 DFT+U on NiO: define the subspace before choosing U
- 5.1 Al(001) slab: separate thickness from vacuum