5.3 GIAO NMR: shielding is not chemical shift

These are unexecuted teaching inputs and starting models. Original diagrams are schematics, not calculated results. Validate version-specific syntax, licensed or authorized data, numerical convergence and the scientific model before using this workflow.

5.3.1 Model, units and provenance

Geometry in Å; electronic energy in hartree; vibrational wavenumbers in cm⁻¹. Check each printed field and keep thermal and standard-state terms distinct.

Shared inputs, conventions and evidence

Original schematic: GIAO NMR: shielding is not chemical shift. No numerical results are claimed.
Original schematic: GIAO NMR: shielding is not chemical shift. No numerical results are claimed.

5.3.2 Unexecuted inputs and explicit deltas

Use the accompanying instructions to identify the parent calculation and placement of every delta; a snippet is not automatically a standalone input. Preserve all blank-line and file-provenance requirements.

5.3.2.1 Input block 1

%chk=formaldehyde19.chk
%mem=2GB
%nprocshared=2
#p B3LYP/6-31+G(d,p) Opt=Tight Freq
   SCF=(Tight,XQC) Int=UltraFine

Formaldehyde geometry and frequencies for NMR

0 1
C    0.000000    0.000000    0.000000
O    0.000000    0.000000    1.210000
H    0.935000    0.000000   -0.585000
H   -0.935000    0.000000   -0.585000

--Link1--
%chk=formaldehyde19.chk
%mem=2GB
%nprocshared=2
#p B3LYP/6-31+G(d,p) NMR=GIAO Geom=AllCheck Guess=Read
   SCF=(Tight,XQC) Int=UltraFine

5.3.2.2 Input block 2

%chk=methane19.chk
%mem=2GB
%nprocshared=2
#p B3LYP/6-31+G(d,p) Opt=Tight Freq
   SCF=(Tight,XQC) Int=UltraFine

Methane geometry and frequencies for the teaching reference

0 1
C    0.000000    0.000000    0.000000
H    0.630000    0.630000    0.630000
H    0.630000   -0.630000   -0.630000
H   -0.630000    0.630000   -0.630000
H   -0.630000   -0.630000    0.630000

--Link1--
%chk=methane19.chk
%mem=2GB
%nprocshared=2
#p B3LYP/6-31+G(d,p) NMR=GIAO Geom=AllCheck Guess=Read
   SCF=(Tight,XQC) Int=UltraFine

5.3.3 Worked investigation

5.3.3.1 Question, intuition, and prerequisites

Gaussian computes a nuclear magnetic shielding tensor: the electronic response that changes the field felt by a nucleus. Experimental chemical shifts are referenced differences. A shielding value printed in ppm is not already a TMS-referenced chemical shift. This exercise uses formaldehyde as the sample and methane as a deliberately simple computational reference for both ¹H and ¹³C. Methane is not being assigned the conventional TMS experimental reference. Prerequisites: converged molecular structures and recognizing equivalent atoms. Use the same shielding method, basis, and physical environment for sample and reference.

5.3.3.2 Complete sample and reference jobs

Save the first block as formaldehyde19.gjf

See input block 1 above.

Save this independent reference job as methane19.gjf

See input block 2 above.

5.3.3.3 Numbered workflow

  1. Complete both jobs and verify that each optimized structure is a minimum before trusting its NMR step. Formaldehyde has six vibrational modes; methane has nine, including degeneracies.
  2. In the shielding output, copy atom index, element, Isotropic, and anisotropy. Map every atom back to the optimized structure. Do not confuse the output with spin–spin coupling constants.
  3. Average the four symmetry-equivalent methane proton shieldings. Compare this average with each formaldehyde proton shielding. Compare carbon only with the methane carbon, never with the proton reference.
  4. Report \(\Delta\delta_{\mathrm{CH_4}}\approx\sigma_{\mathrm{iso}}(\mathrm{CH_4})-\sigma_{\mathrm{iso}}(\mathrm{sample})\) separately for ¹H and ¹³C. Label the result “calculated shift relative to methane”.
  5. For a conventional TMS comparison, either calculate TMS at the same level and use its appropriate equivalent nuclei, or use a justified calibration whose reference convention is explicitly documented. A known reference shift is added to the computed shielding difference: δsample ≈ σref−σsample+δref.

5.3.3.4 Read and check

The isotropic shielding equals one third of the tensor trace. More shielding means a smaller referenced shift under the usual convention. Arithmetic example only: if a reference proton shielding were 31.0 ppm and a sample shielding 22.0 ppm, their calculated reference-relative difference would be +9.0 ppm. These are invented values, not outputs from the above jobs. Symmetry-equivalent methane proton shieldings should agree within numerical precision; a spread around 0.01 ppm or larger is a useful trigger to inspect geometry, convergence, and equivalence, not a universal failure threshold. The two formaldehyde protons should likewise be equivalent in this isolated equilibrium model.

Do not subtract shieldings belonging to different isotopes/elements as if they shared one direct reference. Negative shielding is possible and not intrinsically an error. GIAO addresses gauge-origin behavior; it does not remove functional, basis, geometry, solvent, or conformational error. A single gas-phase structure does not predict solution exchange averaging. The economical teaching basis is not a claim of high-accuracy NMR performance. If a larger basis changes the sample and reference by similar amounts, their difference may be more stable than either absolute shielding, but this must be tested.

5.3.3.5 Exercise

EN exercise: Construct a worksheet with atom, isotope, isotropic shielding, reference shielding, computed difference, and reference convention. Repeat both shielding calculations with 6-311+G(2d,p) while retaining the original geometries; clearly label this as a property-basis test. Which changes more: absolute shieldings or referenced differences?

5.3.5 Sources and further reading